Raman Rxn5 analyzer
Field of application
The Raman Rxn5 process analyzer is an industry-leading, turn-key, laser-based analyzer powered by Kaiser Raman technology. It provides quantitative chemical composition measurements using Raman spectroscopy. The design of the Raman Rxn5 incorporates customer requirements for serviceability and hazard-area certification, provides a compact footprint, and minimizes utilities consumption. The high optical efficiency of the analyzer makes it ideal for typical gas-phase sample measurements.
Process measurement points:
Typical industries:
Benefits
Non-destructive analysis of gases, including homonuclear diatomics (H2 , N2 , O2 )
Compact, smaller than most wall-mount gas chromatographs (GCs)
Can replace up to four traditional analyzers with a single base unit and four probes
Rugged with minimal utility requirements, no sample transport, and no consumables (columns, valves, gases, pumps)
Minimal analyzer technician time with maximum technician safety (no toxic gases are transported to the analyzer)
Measures four streams simultaneously for faster multi-channel results
-20 to +50 °C operating environment
Extended selection
High-end products
Highly functional and convenient
Technical excellence
Simplicity
©Endress+Hauser
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Loading alternative products
Success stories
Measuring hydrogen quality in real time
Enapter uses optical analytical measurement technology from Endress+Hauser to determine the purity of hydrogen produced. Find out more!
Read the full story
LNG: truck loading
Find out how to accurately measure the composition of LNG at truck loading with the use of a Raman Rxn4 analyzer.
Read the full story
Temperature
Operating: -20 to 50 °C / -4 to 122 °F Recommended storage: -30 to 60 °C / -22 to 140 °F
Relative humidity
0 to 90 %, non-condensing
Input voltage
90-264 VAC, 47-63 Hz standard
Power consumption (W)
<300 (max) <300 (typical start-up) <200 (typical running)
Unit dimensions (width x height x depth)
457 x 834 x 254 mm 18.00 x 32.84 x 10.00 inch
Sampling probe compatibility
Installation options
IP 56 wall-mounted, sealed/purged enclosure
Hazardous area certifications
Most downloaded
Raman Rxn5 Technical Information
English version - 11/2023
System design and specifications for the Raman Rxn5 analyzer -
powered by Kaiser Raman technology
EN
DE ES IT JA PT RU ZH
21/11/2023
Language:
English
Version:
21/11/2023
File size:
1.2 MB
File name:
TI01646CEN_0222.pdf
85 documents
Raman Rxn5 Technical Information
System design and specifications for the Raman Rxn5 analyzer - powered by Kaiser Raman technology
EN
German Spanish Italian Japanese Portuguese Russian Chinese
21/11/2023
Language:
English
Version:
21/11/2023
File size:
1.2 MB
File name:
TI01646CEN_0222.pdf
Raman RunTime v6.5 Operating Instructions
Commissioning, operation, and maintenance details for Raman RunTime v6.5 software
EN
German Japanese
16/11/2023
16/11/2022
31/12/2020
Language:
English
Version:
16/11/2023
File size:
6.7 MB
File name:
BA02180CEN_0423.pdf
Raman Rxn5 Operating Instructions
Commissioning, operation, and maintenance details for the Raman Rxn5 analyzer - powered by Kaiser Raman technology
EN
German Spanish Italian Japanese Portuguese Russian Chinese
21/11/2023
Language:
English
Version:
21/11/2023
File size:
2.8 MB
File name:
BA02179CEN_0323.pdf
LNG parameters & calibration
Operating Instructions
A complete overview of the LNG parameters and calibration for the Raman analyzer
Language:
English
Version:
21/08/2024
File size:
865.4 KB
File name:
BA02371CEN_0124.pdf
Raman Rxn5 Brief Operating Instructions
Quick start guide for the Raman Rxn5 analyzer - powered by Kaiser Raman technology
EN
German Spanish Italian Portuguese Russian Chinese
21/11/2023
Language:
English
Version:
21/11/2023
File size:
1.1 MB
File name:
KA01554CEN_0222.pdf
LNG analyzer performance verification kit Installation Instructions
Instructions for use of the LNG analyzer performance verification kit
Language:
English
Version:
30/03/2023
File size:
442.7 KB
File name:
EA01470CEN_0123.pdf
Raman Rxn5 Safety Instructions
Hazardous area certifications and installation instructions for the Raman Rxn5 analyzer - powered by Kaiser Raman technology
EN
German Spanish Italian Japanese Korean Portuguese Russian Chinese
07/12/2023
Language:
English
Version:
07/12/2023
File size:
1.6 MB
File name:
XA02746CEN_0222.pdf
Raman Rxn5 analyzer - Laser-based composition analysis
An overview brochure about our Raman Rxn5 analyzer (including the Raman Rxn-30 probe, the Rxn-40 probe, and the Rxn-41 probe), a Raman spectroscopy analyzer system for gas phase measurements powered by Kaiser Raman technology.
Language:
English
Version:
28/10/2021
File size:
499.9 KB
File name:
PU01444CEN_0121.pdf
石油・ガスおよび化学産業向け
ラマン分光計アプリケーションガイド
- ガスストリームおよびLNGの組成分析
化学産業および石油・ガス産業におけるガスストリームおよび LNG の組成分析用(Raman Rxn4 アナライザー、Raman Rxn5 アナライザ ー、Raman Rxn-30 プローブ、Raman Rxn-41 プローブを含む)、 Kaiser Raman テクノロジーによるラマン分光アナライザーおよび プローブ製品ラインアップのご案内です。
Language:
Japanese
Version:
13/05/2024
File size:
4.2 MB
File name:
PU01445CJA_0121_RamanAnalyzer_AppGuide_OilGas_ChemInd.pdf
Raman analyzer application guide for the oil & gas and chemical
industries - Composition analysis of gas streams and LNG
A guide to our Raman spectroscopy analyzer and probe portfolio, powered by Kaiser Raman technology, for composition analysis of gas streams and LNG (includes the Raman Rxn4 analyzer, the Raman Rxn5 analyzer, the Raman Rxn-30 probe, and Raman Rxn-41 probe) in the chemical industry and oil & gas industry.
Language:
English
Version:
08/12/2021
File size:
2.5 MB
File name:
PU01445CEN_0121.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
EO fiber cable pulling kit
Wireless keyboard with trackpad
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our privacy policy .
Customize
Accept only essential
Accept all